DWX-53DC | ||
Compatible Materials | PMMA, Zirconia, Wax, Composite Resin, PEEK, Gypsum, Glass-Fiber-Reinforced Resin, Pre-Sintered Chromium Cobalt | |
---|---|---|
Spindle Speed | 30,000 RPM | |
Rotary Axis | A | ± 360° |
B | ± 35° | |
Air Pressure Requirements | 0.4 Mpa | |
External Dimensions | Width, Depth, Height | 23.62 in. x 29.25 in. x 32.75 in. |
Weight | 264.55 lbs. (120 kg) | |
Disc Changing Time | 1 minute, 7 seconds | |
Material Adapter Compatibility | Standard Adapter: ZMA-53DC | Open-Edge Adapter: ZMA2-53DC |
# of Material Adapter Patterns | 100 | |
Additional Features | Redesigned, more robust spindle for 3x the gripping power with PMMA applications. Built-In Integrated Webcam, Thermohydrometer Accelerometer Sensors | |
Accessories Included | Built-In Integrated Webcam, Material Adapter Disc Rack (ZR-53DC), Standard Material Adapters (6-Pack, ZMA-53DC), Open-Edge Material Adapter (ZMA-53DC), 4.0 mm Roughing Tool (ZRB-200D), Diamond-Like Coated (DLC) Milling Tool Set (ZPB-100D, ZPD-50D, & ZPB-30D) | |
Attachable Bur | Shank 4 mm (Diameter), 40-55 mm (Length) | |
Loadable Workplace | Step Sectdon: 98.5 mm Diameter, 10 mm Height; Body Section: Max Height 60 mm |
MEDICAL ELECTRONICS
Description
ImageWorks Panoura X-Era Panoramic and 3D CBCT Imaging System (With Acquisition PC)
CONDITION: New, Model 9992451000
FEATURES:
0.2 mm focal spot (smallest in the industry)
16 bit sensor (highest in the industry)
Direct Conversion sensor
Manufactured in Japan
Clip FMX from Panoramic
Easy to Use and a Great Price
Integrates with all Major Software
BENEFITS:
Multiple Fields of View from 6 cm x 4 cm up to 16 cm x 8 cm
Ideal for all applications including Endo, Implants and Airway
Gorgeous Image quality at all levels
Low dosage mode emits less radiation than a traditional intraoral FMX exam
Front-viewing patient positioning
Ceph model has option of dedicated ceph sensor
360 degree rotation
Intuitive interface means less training and no mistakes
Simple positioning also enhances patient comfort
Integrates with all Major Software
MANUFACTURER: ImageWorks
DGSHAPE takes a purpose-driven approach to the process of innovation. It’s a combination of product and opportunity that enables us to consistently deliver quality and value to the dental lab community. This well-structured solution is in a class of its own, the NEXT GENERATION of DWX…the new DWX-53DC.
- Elegant new design
- New and improved high-performance spindle
- Sealed chamber to keep milling waste isolated
- Built in webcam for real-time mill monitoring
- DGSHAPE CLOUD performance visualisation software
- Optional tablet integration
Clean Precision Laser Beam from
the High-Peak Power CO2 LASER
The Spectral absorption of water on a wavelength of 10,600
nanometers enables CO2 surgical laser to cut, vaporize and
coagulate tissue by adjusting Power Density and Energy Level.
More Precisive, More Safe
Edge Pulse of Edge ONE™ conveys energy to the depth of skin and can generate a very narrow ablation zone to form the extent of thermal diffusion limited to the surrounding tissue.
Limited extend of thermal diffusion reduces the pain at time of treatment and the forming of scar after treatment
- A variety of spot sizes
- Much detailed spot size of 120 μm, and wide coverage of 800 μm with fast wound healing time by various beam pattern of heat delivery method.
- Various beam pattern
- Flexible approach to various application.
- Prevents heat diffusion to surrounding normal tissues by managing space between
Fractional Mode
Support treating localized skin lesion and tissue incision by Surgical Tip.
Surgical Mode
A laser Beam becomes powerful as well as being highly concentrated for the interaction with tissue. The outstanding precision by the ultra pulse of Edge ONE™ specially makes the laser beam very accurate without damaging the surrounding tissue and it can also be applied to a very small lesions less than 1 millimeter.
- [Surgical Mode]
- [Fractional mode]
Computerized Electrophysiology Device Tomey EP-1000 Pro, NEW!
The EP-1000 Pro is the essence of 10 years experience of developing electrophysiology instruments. It is an ISCEV conform electrophysiology diagnostic device in a compact shape. Standard examinations are: ERG, VEP, EOG, PERG and SWEEP VEP.
The examination procedure is automated and the easy-to-use program steps will guide you through the complete examination. That makes it possible to delegate this kind of examination to assistants. The EP-1000 Pro workstation provides full com-
puterized control of electrophysiology testing and data management.
Switching to a flash stimulated examination will automatically occlude the integrated monitor of the Ganzfeld dome. Selecting of pattern stimulation automatically opens the occlusion. These filters are automatically inserted upon respective program selection. Thus it represents the second level of EP-1000 Pro evolution.
Overview
The Canon CR-2 PLUS Digital Non-Mydriatic Retinal Camera provides Color and Fundus Autofluorescence (FAF) imaging within a small compact design. Geographic Atrophy, Macular Degeneration, Glaucoma, Diabetic Retinopathy and other conditions that can affect vision may also be identified and monitored using FAF mode. Using invisible infrared alignment light, the digital non-mydriatic camera may image patients with pupils as small as 3.3 mm (small pupil mode) without dilation drops. This is especially useful when performing retinal screenings or expediting routine retinal imaging exams during office visits.
Features
Non-Mydriatic Fundus Autofluorescence (FAF) Photography
Fundus Autofluorescence (FAF) helps monitor macular waste (e.g. lipofuscin) which can accumulate in the Retinal Pigment Epithelial (RPE) layer. The accumulation of macular waste can cause conditions such as Age-Related Macular Degeneration (AMD) which can lead to reduced vision. The FAF mode may be selected by pressing only one button.
Digital Filter Processing
Red-Free and Cobalt digital filters are included and provide enhanced screening exams. Red-Free is used for evaluating the Retinal Nerve Fiber Layer (RNFL) and vascular structure of the retina associated with documenting Glaucoma, Diabetic Retinopathy or Hypertension. The Cobalt filter is also used for evaluating the RNFL, as well as Optic Disc and Optic Disc Drusen. Additionally, Green (Vascular view) and Red channel (Choroid view) digital filter views are also included.
Compact and Lightweight
The small design of the CR-2 PLUS facilitates portability when needed using an optional hard shell transport case sold separately. Canon instrument tables (sold separately) may comfortably fit both the camera and computer workstation (sold separately). The space saving design also allows for use in limited office space environments.
Dedicated EOS Camera Technology
High quality diagnostic images are obtained using a dedicated camera for the CR-2 PLUS which incorporates a large, high-definition CMOS sensor with 18 megapixels. When the camera cover is removed, the LCD may be adjusted to a variety of titled angles to suit the user's point of view.
Low Flash Intensity and ISO Sensitivity
The low flash intensity of the CR-2 PLUS minimizes miosis, thus shortening the time required for taking multiple view exams or stereo images. The reduced brightness improves patient comfort and reduces the "ghost" image the patient sees after an exposure. A wide range of low ISO speeds are supported including ISO 200, 400, 800, 1600, 3200 and 6400.
Automatic Exposure Function
The CR-2 PLUS measures the volume of infrared light from the retina and automatically adjusts the flash intensity for observation and photography. This feature may be set to ON/OFF and can be adjusted using the operation panel.
Control Panel
The simplified design of the control panel can be easily handled by an examiner. The one-handed joystick may be used to position the camera to acquire the desired image. In darkly lit rooms, the operation panel illuminates for easier navigation. The short main body of the CR-2 PLUS provides minimal distance between the patient and the operator allowing easy access to adjust the patient's position or eyelids.
Retinal Imaging Control Software
Using the Canon Retinal Imaging Control Software (RICS), images can be captured, viewed, processed, printed and saved to a permanent storage database. The Canon RICS complies with the DICOM Standard. Images may be stored as DICOM or JPEG files. For more information, visit Retinal Imaging Control Software.
DICOM is a registered trademark of the National Electrical Manufacturer Association for its standard publications relating to digital communications of medical information.
Specifications
Optional Accessories
External Eye Fixation Lamp Unit
Hard-shell Carrying Case
Chin Rest Paper (500 sheets)
General
Type of Photography Color, Digital Red-Free, Digital Cobalt, Fundus Autofluorescence (FAF)
Angle of View 45° (35° SP Mode)
Magnification 2X Digital
Minimal Pupil Size 4.0 mm (3.3 mm SP Mode)
Focus Adjustment Type Split-line Adjustment
Patient Diopter Compensation Range Without Compensation Lens: -10 to +15D
With "-" Compensation Lens: -31D to -7D
With "+" Compensation Lens: +11D to +33D
Light Source Observation: Infrared
Photography: Xenon tube
Canthus Mark 420 mm From Base
Internal Eye Fixation LED Dot Matrix
External Eye Fixation White LED (Sold Separately)
Working Distance 35 mm
Working Distance Adjustment Anterior Observation: Double Image Match Method
Fundus Observation: Working Distance Dots
Sensor Resolution 18.0 Megapixels
Camera Dedicated EOS Camera for CR-2 PLUS (Bundled)
Monitor 3.0 inch LCD Monitor
External Monitor (Optional)
Auto Function Automatic Exposure
Mount Movement Front and Back 70 mm
Side to Side 100 mm
Up and Down 30 mm
Chin Rest Movement 60 mm
Electrical and Environmental
PC Interface USB 1.1, USB 2.0
Power Supply AC 100-240V 50/60Hz
Operating Environment Temperature: 50° to 86° Fahrenheit (10° to 35° Celcius)
Humidity: 30% RH to 90% RH (No Condensation)
Atmospheric Pressure: 800 hPa to 1060hPa
Physical Characteristics
Dimensions (W x D x H) 12 x 19.7 x 20.2 inches
(305 x 500 x 513 mm)
Weight 43.9 lbs (19.9 kg)