OPHTHALMOLOGY EQUIPMENT
EP-1000 is an ophthalmologic diagnostic unit for a complete examination of the retina’s function, the visual pathway, and the optic nerve. A variety of diagnostic procedures can be performed, including ERG, VEP, MERG, MVEP, and EOG. This unit can only be operated by physicians and medically trained technical assistants. EP-1000 complies with the ISCEV’s standards (International Society for Clinical Electrophysiology of Vision).
Computerized Electrophysiology Device Tomey EP-1000 Multifocal, NEW!
Whenever you need detailed information,
the Multifocal will be your first choice
The EP-1000 Multifocal (mf) allows you to do all mf standard tests:
mfERG flash (FOK, SOK, flicker)
mfERG pattern (9 pattern for stimulation)
mfVEP (dartboard stimulation) for analysing local retina functions
Accessories and Optionals Analyses can be displayed in curves, values, 2D, 3D, rings, quadrants, groups and table.
Cross-target for macula dystrophy patients time
Mf pattern ERG with scrolling text target
Full access to all settings
e. g. position of the fixation target
No matter if you want to receive standardised clinical data or are heading towards a more scientific
oriented environment Tomey offers you the perfect individual electrophysiology solution.
The EP-1000 Multifocal is based on short M-sequences. This allows you to re-check all conditions of the exam, such as proper fit of electrodes or acceptable responses within a very short time (8 sec.).
With the fixation control hexagon the results can be controlled after every cycle. You dont have to wait until the end of the whole examination for controlling the fixation of the patient.
Different fixation targets are available: the cross-target covers the whole stimulation monitor to make exams possible for macula dystrophy patients. The changing
animal target is for children and the scrolling text target for all other patients.
Digital Fundus Camera Canon CF-1 inkl. Canon EOS-50D Mark II MED, NEW!
Overview:
The CF-1 Digital Mydriatic Retinal Camera is easy to use and efficient for both doctor and photographer. When used with a Canon EOS® digital SLR camera (sold separately), users can enjoy renowned Canon optical technology for superb imaging quality. User-friendly control software helps to ensure efficient workflow, potentially resulting in increased patient throughput. The CF-1 Digital Mydriatic Retinal Camera provides high-resolution color, red free, and fluorescein angiography imaging performance and heightened efficiency for eyecare professionals.
Features
Color, Red-Free, and Fluorescein Angiography Imaging
The CF-1 Digital Mydriatic Retinal Camera integrates a digital SLR camera from Canon's EOS series to achieve high resolution images with excellent detail, contrast, and color fidelity.
Easy Alignment and Focus
The 50-degree view angle enables easy alignment and focus with less flash flare, even with smaller pupil sizes. Only a low amount of light is needed to capture clear images.
2x Digital Magnification
Zoom the retina to 2x magnification and the system automatically crops out the peripheral edges of the image so the region of interest is larger in the frame.
Ergonomic Control Panel
Operator controls for key features such as shutter release, lamp setting, ISO adjustment, and mode switching are grouped together for one-handed operations in darkened exam rooms.
Corneal biomechanical properties influence the results and outcomes of ocular measurements and procedures, and may hold clues to diagnosing and managing ocular diseases.
Until now, assessing the biomechanical properties of corneal tissue has not been possible, confining practitioners and researchers to measuring purely geometrical aspects of the cornea, such as thickness and topography.
The Reichert Ocular Response Analyzer provides a new measurement of corneal tissue properties called Corneal Hysteresis (CH) that is a result of viscous damping in the corneal tissue.
How does it work?
The Ocular Response Analyzer utilizes a rapid air impulse, and an advanced electro-optical system to record two applanation pressure measurements; one while the cornea is moving inward, and the other as the cornea returns. Due to its biomechanical properties, the cornea resists the dynamic air puff causing delays in the inward and outward applanation events, resulting in two different pressure values:
The average of these two pressure values provides a repeatable, Goldmann-correlated IOP measurement (IOPG). The difference between these two pressure values is Corneal Hysteresis (CH); a new measurement of corneal tissue properties that is a result of viscous damping in the corneal tissue. The ability to measure this effect is the key to understanding the biomechanical properties of the cornea.
The CH measurement also provides a basis for two additional new parameters: Corneal-Compensated Intraocular Pressure (IOPCC) and Corneal Resistance Factor (CRF). IOPCC is an Intraocular Pressure measurement that is less affected by corneal properties than other methods of tonometry, such as Goldmann (GAT). CRF appears to be an indicator of the overall resistance of the cornea.
Product Features:
Comprehensive Pressure and Cornea Information
*
IOPCC (Corneal Compensated IOP) - New IOP measurement less affected by corneal properties.
*
CH (Corneal Hysteresis) - Measure of viscous damping in the cornea, providing new indicators for disease diagnosis and management.
*
CRF (Corneal Resistance Factor) - Measure of the overall rigidity of the cornea.
*
IOPG (Goldmann Correlated IOP) - Traditional IOP measurement for historical reference.
Advanced Technology
*
Patented dynamic bi-directional applanation process enables the only direct measure of corneal biomechanical properties.
*
Eliminates operator variance by utilizing microprocessor control technology and objective measurement criteria.
*
Patient and Operator Friendly
*
No chinrest and a soft, quiet air puff make the Ocular Response Analyzer a comfortable, non-intimidating experience for your patients.
*
Fully automatic alignment and measurement provides fast, repeatable results, allowing any member of your staff to conduct an exam.
Powerful Software Package
*
Enables automatic data capture of all measurements for analyzing trends, treatment efficacy, and diurnal variations.
*
Comprehensive patient management database simplifies record keeping.
*
Review results for a single patient, or data for an entire group of patients for population statistical analysis.
*
Comprehensive printout for hard-copy results.
*
Export data for use in other applications.
bon COBRA 5. MP non-mydriatic digital fundus camera, NEW!
Incl. chinrest and software
COBRA - The next generation of non-mydriatic fundus camera.
Content:
Cobra fundus camera incl. chin rest
Phoenix suite software
b o n delivers the innovative non-mydriatic digital fundus camera that integrates every function required for easy retinal screening.
Integrating an innovative imaging optical system, Cobra realizes digital fundus imaging of high resolution and fine gradation.
Ergonomically designed Cobra provides clear and detailed display of the entire fundus image at true 60° x 45° field of view.
The system offers retinal photography with minimum flash exposure allowing quick and efficient fundus photography, thereby minimizing patient discomfort.
Cobra shares the use of the high resolution CCD camera for alignment (IR illumination) and capture (White light flash).
Non-mydriatic
Cobra only needs a minimum pupil diameter of 2,2 mm and a room with standard lighting conditions.
Anterior Segments
Thanks to its variable focus options Cobra also provides pictures of the anterior segments of the eye.
High-speed image transfer to PC
Firewire connection to a PC allows quick and easy transfer of the images. The data are saved in a database through the Phoenix Software in Stand-Alone or network configuration.
DICOM connection can be achieved transferring images to a compatible server.
Phoenix Software imaging and archiving features
Sophisticated imaging functions are incorporated, including image processing features, drawing, measurement, and panoramic imaging for large field analysis.
With Phoenix it is easy to print and save structured reports on the patient archive.
Image export is available in many image formats. The data can be transferred to a DICOM (Digital imaging and Communications in Medicine) compatible server.
Imaging features
# Zoom effects
# Color control and filtering
# Measurement
# C/D ratio, Disc HV, Cup HV
# Drawing (text / objects can be inserted)
# Edge enhancement
# Grey scale
# contrast RGB
# Red-free and channel splitting
# Color inversion
# Brightness, Contrast and Gamma control
Automated Perimeter Kowa AP-7000, NEW!
Automated perimeter for both static and kinetic perimetry
Next generation perimeter with the gold standard threshold test
The AP-7000 is Kowas next generation automated perimeter that offers an extensive variety of test strategies and screening
programmes. It provides reliable and consistent assessment results due to its normalised database.
Full threshold modes offer macular, central and peripheral coverage up to 80° whilst screening modes provide swift evaluation of the visual field for relative or absolute scotomas. To shorten test times quick modes are available for both threshold and screening modes. Furthermore, by automatically correlating the fundus image (from a fundus camera, OCT or SLO) with the static visual field, early detection of glaucoma is possible.
With its ergonomic, compact design, the AP-7000 offers additional comfort to patients, easy operation for the clinician and fits perfectly within the practice.
Fundus Oriented Perimetry
Static perimetry test can be applied to abnormal sites on a fundus images, such as a fundus photograph, OCT or SLO.
Threshold test within the central 10°, custom optional threshold that allows selection of any desired test point, and custom optional screening tests are available.
Threshold Macula 2 test, Custom opticonal threshold test and Custom optional screening test are available.
Threshold Macula 2 test examins within the central 10°, Custom optional tests allow selection of any desired test points.
In addition to test within the central 30° that can observe the progression of glaucoma, test is possible in a wide variety of range, including central 10°, which can identify visual field abnormalities in the macula.
Analytical Indices
GHT (Glaucoma Hemifield Test)
For this index, threshold center test points are divided into ten sectors, and corresponding sectors above and below the axis of the horizontal median are compared.
VFI (Visual Field Index)
A percentage index in which a normal visual field is 100% and total loss of field is 0%
Anderson's Criteria Diagnostic Support Function
If one or more of three consecutive points satisfy one or more of the conditions "PSD has p<5%", "GHT outside normal limits", or "patern deviation probability plot shows a cluster of three or more nonedge points that have p<5%, and one of the points has p<1%" this indicator judges the condition to be a glaucoma visual field abnormality. (The physician must judge whether the three points match the NFL movement.)
Chronological Change Display
Test result analytical indices can be graphically displayed as time series data to give a clear grasp of changes over time in the tested eyes.
Predictive Display
Predictive graphs are displayed from calculations of linear rates of changes in analytical indices. This function predicts what values of MD and VFI (Visual Field Index) will be reached at what age, if current rates of change in those values continue.
Convenient Tabbed User Interface
Main operation buttons are grouped at the top of the page, and buttons are laid out to follow the progression of tests, from patient information entry through test program selection to result display.
4-zones measurement that goes beyond screening, and programs using probability values (p-values) in intensity steps, are among the features that enable effective test in less time.
Running tests with intensity of probability value (p-value) makes it possible to display the difference between the measured value and the normal value for each age as a p-value, so that evaluation equivalent to total deviation in thresholds can be performed in a shorter time.
"Automatic measurement function", using many median patterns, "Manual measurement function", allowing free drawing of isopters, and "auto + manual measurement function", which allows any drawing of median after automatic measurement, are among the diverse measurement method options available.
Automatic Perimeter Zeiss Humphrey Field Analyzer HFA 3 / 830, NEW
Incl. table, printer, keyboard, mouse
The New Humphrey Field Analyzer 3 from ZEISS Sets a New Standard for Efficient Visual Field Testing
New HFA3 offers gold-standard perimetry performance with technological advances such as automated trial lens correction that are designed to save time and reduce errors, plus test results equal to and interchangeable with test results from previous Humphrey perimeters.
The HFA3 is the first perimeter to introduce patented Liquid Lens technology, which saves time, simplifies set-up and reduces the possibility of human error in trial lens correction. In perimetry, a trial lens provides the refractive correction needed so each patient can see clearly during the test. The HFA3 replaces the old manual process with a patented Liquid Trial Lens, which automatically delivers the appropriate refractive correction using measurement information entered into the instrument.
The HFA3 provides a streamlined and faster workflow with an array of new features designed to:
Improve confidence in test results with RelEYE, which allows doctors to instantly review the patients eye position, at any stimulus point. RelEYE data is available on the instrument and when reviewing test results with FORUM® Glaucoma Workplace. It may reveal common testing problems, such as droopy lids (ptosis) or misalignment of the eye relative to the trial lens holder.
Save time with an intuitive new SmartTouch interface, which reduces the number of steps required for the technician to start a perimetry exam. Faster gaze tracking provides information that helps doctors assess the reliability of test results. The gaze tracker on the HFA3 provides faster initialization and works on a wider spectrum of patients, compared to earlier models of HFA.
Make test administration simpler, with an easy-to-use kinetic graphical user interface with a full 180-degree field of view.
HFA3 provides a streamlined and faster workflow with an array of remarkable new features designed to:
Reduce setup time with a single trial lens. Using liquid pressure, the new Liquid Trial Lens, instantly delivers each patient's refractive correction, with the touch of a button.
Save time with an intuitive new SmartTouch interface that helps to shorten chair time.
Accelerate clinic flow with equipment that can be learned quickly and operated easily.
Improve confidence in visual field test results with RelEYE. Instantly review the patient's eye position, at any stimulus point.
Gain peace of mind with seamless transferability of legacy data from the HFA II and HFA II-i to HFA3.
Easy to use kinetic graphical user interface with full 180° visual field testing range.
Liquid Lens technology: One lens, less time
The new automatic Liquid Trial Lens reduces patient setup time by automatically loading the patients refractive correction from their previous exam. The result is faster patient flow and reduced chance of error when selecting a lens during test setup.
SmartTouch interface: Ready, set, test!
The new HFA3 platform gets you up and running with fewer touches simply select the patients name and press Start, all using an all-new color graphic user interface.
Exclusive gaze tracking: On track? Know right now
Save time with improved gaze tracking initialization.
Kinetic Perimetry: Significant advancements
Easy to use kinetic graphical user interface with full 180° testing range.
HFA review with FORUM Glaucoma Workplace from ZEISS
Review quantitative and qualitative information from all standard HFA analyses, in an easy-to-read format
Change baselines and capture, track and measure progression simply and easily with Guided Progression Analysis (GPA)
Use RelEYE to preserve an image of the patients eye at every stimulus presentation during a SITA Standard test
Check for ptosis or trial lens rim artifacts as well as assess patient's compliance with RelEYE in both GPA and single-field analysis modes
Work with either Mean Deviation (MD) or Visual Field Index (VFI)or both
Generate HFA reports using a MAC or a PC
Humphrey Gold Standards
For years, the Humphrey Field Analyzer has brought certainty to glaucoma diagnosis. As the gold standard of perimetry, it is a critical diagnostic partner in thousands of practices. HFA delivers the interactive analysis you need, when and where you need it.
Visual Field Index (VFI) VFI is a simple and intuitive global index. Its most powerful application is GPA, which trends VFI over time to project remaining vision.
GPA Alert A message in simple language that indicates whether statistically significant deterioration was identified in consecutive visits.
STATPAC The language of perimetry, STATPAC compares results to proprietary age normative and glaucoma databases.
SITA Strategies Unsurpassed in efficiency, SITA is patient responsive: it learns to perform as fast as the patient.
Connectivity HFA3 connects to other HFA3 and HFA II-i perimeters. For comprehensive connectivity, HFA3 can be connected to FORUM with FORUM Glaucoma Workplace. HFA3 also supports common file folder sharing used by most Electronic Medical Record Systems (EMRs).
Automatic Perimeter Zeiss Humphrey Field Analyzer HFA 3 / 850, NEW
Incl. RelEye, Table, printer, keyboard & mouse
The New Humphrey Field Analyzer 3 from ZEISS Sets a New Standard for Efficient Visual Field Testing
New HFA3 offers gold-standard perimetry performance with technological advances such as automated trial lens correction that are designed to save time and reduce errors, plus test results equal to and interchangeable with test results from previous Humphrey perimeters.
The HFA3 is the first perimeter to introduce patented Liquid Lens technology, which saves time, simplifies set-up and reduces the possibility of human error in trial lens correction. In perimetry, a trial lens provides the refractive correction needed so each patient can see clearly during the test. The HFA3 replaces the old manual process with a patented Liquid Trial Lens, which automatically delivers the appropriate refractive correction using measurement information entered into the instrument.
The HFA3 provides a streamlined and faster workflow with an array of new features designed to:
Improve confidence in test results with RelEYE, which allows doctors to instantly review the patients eye position, at any stimulus point. RelEYE data is available on the instrument and when reviewing test results with FORUM® Glaucoma Workplace. It may reveal common testing problems, such as droopy lids (ptosis) or misalignment of the eye relative to the trial lens holder.
Save time with an intuitive new SmartTouch interface, which reduces the number of steps required for the technician to start a perimetry exam. Faster gaze tracking provides information that helps doctors assess the reliability of test results. The gaze tracker on the HFA3 provides faster initialization and works on a wider spectrum of patients, compared to earlier models of HFA.
Make test administration simpler, with an easy-to-use kinetic graphical user interface with a full 180-degree field of view.
HFA3 provides a streamlined and faster workflow with an array of remarkable new features designed to:
Reduce setup time with a single trial lens. Using liquid pressure, the new Liquid Trial Lens, instantly delivers each patient's refractive correction, with the touch of a button.
Save time with an intuitive new SmartTouch interface that helps to shorten chair time.
Accelerate clinic flow with equipment that can be learned quickly and operated easily.
Improve confidence in visual field test results with RelEYE. Instantly review the patient's eye position, at any stimulus point.
Gain peace of mind with seamless transferability of legacy data from the HFA II and HFA II-i to HFA3.
Easy to use kinetic graphical user interface with full 180° visual field testing range.
Liquid Lens technology: One lens, less time
The new automatic Liquid Trial Lens reduces patient setup time by automatically loading the patients refractive correction from their previous exam. The result is faster patient flow and reduced chance of error when selecting a lens during test setup.
SmartTouch interface: Ready, set, test!
The new HFA3 platform gets you up and running with fewer touches simply select the patients name and press Start, all using an all-new color graphic user interface.
Exclusive gaze tracking: On track? Know right now
Save time with improved gaze tracking initialization.
Kinetic Perimetry: Significant advancements
Easy to use kinetic graphical user interface with full 180° testing range.
HFA review with FORUM Glaucoma Workplace from ZEISS
Review quantitative and qualitative information from all standard HFA analyses, in an easy-to-read format
Change baselines and capture, track and measure progression simply and easily with Guided Progression Analysis (GPA)
Use RelEYE to preserve an image of the patients eye at every stimulus presentation during a SITA Standard test
Check for ptosis or trial lens rim artifacts as well as assess patient's compliance with RelEYE in both GPA and single-field analysis modes
Work with either Mean Deviation (MD) or Visual Field Index (VFI)or both
Generate HFA reports using a MAC or a PC
Humphrey Gold Standards
For years, the Humphrey Field Analyzer has brought certainty to glaucoma diagnosis. As the gold standard of perimetry, it is a critical diagnostic partner in thousands of practices. HFA delivers the interactive analysis you need, when and where you need it.
Visual Field Index (VFI) VFI is a simple and intuitive global index. Its most powerful application is GPA, which trends VFI over time to project remaining vision.
GPA Alert A message in simple language that indicates whether statistically significant deterioration was identified in consecutive visits.
STATPAC The language of perimetry, STATPAC compares results to proprietary age normative and glaucoma databases.
SITA Strategies Unsurpassed in efficiency, SITA is patient responsive: it learns to perform as fast as the patient.
Connectivity HFA3 connects to other HFA3 and HFA II-i perimeters. For comprehensive connectivity, HFA3 can be connected to FORUM with FORUM Glaucoma Workplace. HFA3 also supports common file folder sharing used by most Electronic Medical Record Systems (EMRs).
The EM-4000 offers non-contact examination, auto-alignment and measurement, with automatic analysis of the endothelium layer. The EM-4000 is professional and quick (4 seconds for both eyes). The auto-alignment technology means reproducibility of the measured areas in insured. The integrated non-contact pachymetry automatically measures with every central examination. The large colour touch screen is used as an operating monitor as well as for displaying all measured values. The EM-4000 has a very large measurement area, with up to 300 counted cells the system assures a representative cell density analysis of your patients’ cornea. Images can be taken at 13 position (the centre and 12 peripheral points). The thickness of the cornea is automatically measured with every central exam. The software evaluates all relevant data respective to the endothelium, such as the density of the cells as well as Polymegathism and Pleomorphism (morphology). High quality images enable discovering irregularities or degeneration of the endothelium possible. For difficult cases you can use the classical L-count function, the Core method and Tomey’s special Dark Area analysis tools.
EM-4000 Features:
- Auto-alignment & auto-measurement
- Integrated non-contact Pachymetry
- 13 measurement areas
- Integrated database
- L-Count, Trace, Core and Dark Area methods
- Counts up to 300 cells
- Integrated printer
b o n PERSEUS Specular Microscope
Non-contact examination, auto-alignment and automatic vertices-based analysis of the endothelium layer within a few seconds, makes working with the Perseus smart, professional and accurate.
Friendly user interface: the examination is performed via very user-friendly touch screen alignment.
Wide measurement area: the wide measurement area makes it possible to count up to 300 cells (average value on normal eyes) and enables the analysis software to get a reliable cell density along with the analysis of cell size and shape.
Minimum light, maximum comfort: Perseus ensures maximum patient comfort due to the low intensity the light source.
Seven measurement areas: images can be taken at 7 positions (single centre position and six peripheral points).
Pachymetry: non-contact pachymetry is performed on every acquisition
High magnification during analysis makes it possible to zoom into the image seeing the limit of each cell in detail.
This enables the user, via touch screen navigation, to edit individual cells.
Software features: the intuitive software evaluates all relevant endothelium data such as
Number of counted cells
Cell density (number of cells per 1 mm2)
Average dimension of analysed cells
Standard deviation of analysed cell dimension
Coefficient of variation
Statistical distribution of sizes (polymegathism) and shapes (pleomorphism)
ZEISS modern vision testing at its best
Skillful determination of best-corrected visual acuity can be time-consuming, requiring operator experience and various fine adjustments. It is well worth the effort when the result is perfect vision correction, a superior viewing experience and highly satisfied patients – as with the digital phoropter VISUPHOR® 500 and the acuity chart systems VISUSCREEN 100 and VISUSCREEN 500 from ZEISS. Combining comfort and convenience with speed and efficiency, they offer refraction specialists a sophisticated, modular solution.
Made to assist your expertise
> Flexible: Subjective refraction systems from ZEISS are modular and expandable to suit your needs.
> Simple: Acuity charts and phoropter allow easy, intuitive operation via touch-screen interface.
> Efficient: Preconfigured workflows let you get right to work, saving you time preparing refraction tests.
> Connected: You can upload presets from the autorefractor VISUREF® 100 and the digital lensmeter VISULENS® 500 from ZEISS; or directly connect to selected data management systems such as FORUM® from ZEISS.
Simple touch screen control
Simplicity best describes the handling experience of the ZEISS subjective refraction system. The clearly structured user interface makes working with the ZEISS VISUSCREEN/VISUPHOR very easy. With the fully integrated GUI, both the phoropter and acuity screen can be controlled as one subjective refraction unit. Even single-handedly, with the optional, medical grade panel PC or an iPad.
Smart workflow
The ZEISS VISUPHOR 500 enables preconfigured workflows. Thereby, settings for each test are optimally adjusted, fully automatically, making standard refraction tests simple and fast. Settings and workflows can also be individually configured in the freestyle mode. Patient contact with the headrest is continuously monitored and displayed on the screen.
Technical data | ||
---|---|---|
Spherical lenses | –19.00 to +16.75 D (increments: 0.12 / 0.25 D) | |
Cylinder lenses | 0 to ± 8.75 D | |
Cylinder axis | 0 to 180° (increments: 1° steps) | |
PD | 48 to 80 mm | |
Rotary prism | 0 to 20 ∆ | |
Retinoscopy | +1.5 D, +2.0 D | |
Pin hole lens | 2 mm | |
Maddox rod | Right eye: red, horizontal / left eye: red, vertical | |
Red/green filter | Right eye: red / left eye: green | |
Polarizing filter | Right eye: 135°, 45° / left eye: 45°, 135° | |
Split prism | Right eye: 6 ∆ BU Left eye: 10 ∆ BI (up to 5 ∆ complement) | |
Line voltage | 100 – 120 / 200 – 240 V AC ± 10%, 50…60 Hz | |
Power consumption | 145 VA | |
Dimensions (W x H x D) | 361 x 280 x 108 mm | |
Weight | 5 kg | |
Interfaces | 2 x RS232 / Bluetooth | |
System requirements | iPad or iPad Air with iOS 11 or better |
Incl. Nikon SLR and VK-2 software
Features
KOWA nonmyd 7 FUNDUS CAMERA
Digital 16 Mega-Pixels External Integrated Camera Back
Nonmyd Color 45 degree / 20 degree Optical Magnification
Small Pupil Mode
Multiple Step Flash
Focusing/Alignment Dots
Easy to Operate
Specifications
Picture Angle 45 Degrees / 20 Degrees Optical
Working Distance 30mm (distance of examined eye to front end of objective lens)
Minimum Pupil Diameter 3.7mm
Focusing Split Luminous Bars
Working Distance Adjustment 2 Luminous Dot Indication Types (Anterior Chamber / Fundus Electrically Switched)
Internal Fixation Lamp 3 Positions (Central, Nasal, Temporal)
External Fixation Lamp Red Light (Option)
Monitor 5.5" LCD Monitor
Interface IEEE1394
Power-Saving Function Timer
Optical Head Movable 40mm Forward / Backward, Movable 100mm Leftward / Rightward, Movable 30mm Vertically (Electric)
Chinrest Moving Distance Movable 60mm (Electric)
Power Supply Input: AC100V - AC240V, 50 / 60Hz
Dimensions 310 (W) x 504 (D) x 548 (H) mm
Weight 21Kg / 46 Ibs.
VK-2 DIGITAL IMAGING SOFTWARE
Fast Patient Set-up
On Screen Stereo Viewing
Easy Operation
Multi-video Input
FA / Color / ICG / Slit Lamp
Complete Image Manipulation
Bridge Integration with OfficeMate and other popular electronic record management software
Network Ready
Telemedicine Ready
True Merge Function
Addressing all major perimetry needs, the Octopus 900 is the perimeter of choice for anyone who wants diagnostic flexibility to analyse, assess and track patients’ visual fields.
It makes it possible to run standard central and peripheral visual fields with minimum test duration, seamlessly integrated into your practice environment. This supports high patient throughput and effective practice management. With its built-in reliability features, the Octopus 900 is easy-to-use and delivers results you can trust.
FEATURES
- Disease based programs with Octopus Glaucoma(G) & Macula(M) programs. Capable of doing 24-2, 30-2 & 10-2 programs
- TOP Strategy for results in less than 3 minutes per eye. Also includes Dynamic & Normal Strategies
- 100% reliability regarding fixation with Octopus Fixation Control
- Full 90-degree static tests, including: Estermann & Blepharoptosis
- 1 isopter III4e Goldmann Kinetic test
- EyeSuite Global Trend Progression Analysis, as well as, Cluster & Polar Trend Analysis
- Remote database capability for shared viewing station
- Separate computer, monitor, printer & wheelchair accessible table
- Manual & semi-automated Goldmann Kinetic testing
- Custom Static testing
- Blue/Yellow (SWAP), Flicker & Red/White methods
SPECIFICATIONS
OCT Zeiss Cirrus HD-OCT, NEW!
Cirrus HD-OCT Immerse Yourself In the Image.
Some views draw the observer directly into the picture views such as those offered by Cirrus HD-OCT. This new high-performance OCT instrument from Carl Zeiss Meditec offers a quantum leap forward in imaging. Featuring spectral domain technology, Cirrus HD-OCT delivers exquisite high-definition images of ocular structures, precise registration and intuitive, efficient operation.
It's not just spectral domain. It's High-Definition OCT.
Cirrus HD-OCT realizes the superior capabilities of ZEISS optics and provides exquisite high definition images and analyses for enhanced clinical confidence.
Beautiful high definition OCT scans and LSO fundus images provide visualization of retinal structure. HD layer maps and thickness maps reveal the critical details of histology and pathology at a glance.
Designed for Efficiency
Advanced hardware and software facilitate automated alignment and high patient through-put. An elegant user interface and fast electronics mean chair time is shortened.
Integrated Design
The compact, integrated design has a small footprint, so the instrument can fit into even a crowded clinic, and with the 90-degree orientation the operator can easily see the patient during setup and scanning.
Iris Viewer
During scanning the iris viewer facilitates scan placement. Mouse Driven Alignment and image capture is simple and efficient
New Glaucoma Applications
Precise registration and repeatability of RNFL thickness measurement. RNFL thickness display is of a 1.73 mm radius circle around the cup. The center of the cup is automatically identified, eliminating subjectivity. RNFL thickness is displayed in graphic format and compared to normative data
The RNFL thickness map shows the patterns and thickness of the nerve fiber layer The RNFL deviation map is overlaid on the OCT fundus image to illustrate precisely where RNFL thickness deviates from a normal range
Time After Time
Auto Patient Recall assures patient position and instrument setting are repeated from previous visit Automated visit-to-visit registration ensures reproducibility with overlay of the OCT fundus image from the previous scan for verification of scan position
Real-Time Registration
Simultaneous capture of the OCT and the LSO fundus image ensures precise registration between the OCT scan and the fundus image
Slide Navigator
Manipulation of slide bars on any image simultaneously adjusts all corresponding images. Details of pathology can be precisely located for visualization
Cirrus HD-OCT Review Software
Cirrus Review Software brings the power of Cirrus HD-OCT analysis to the exam lane. To streamline office workflow, Cirrus Review Software enables dynamic viewing of images and analyses at a remote location such as a laptop or personal computer.
Cirrus Review Software adds value in these critical areas:
* Allows detailed analysis of data in a doctors office, patient exam lane, or research center.
* Facilitates patient education by bringing dynamic display and 3D Advanced Visualization to a convenient location.
* Increases instrument availability for improved patient workflow.
* Supports simultaneous connection of up to ten review stations.
Cirrus Review provides dynamic viewing capabilities on a Windows based computer connected to a Cirrus 3.0 instrument database through a peer to peer office network. A single review software license allows up to 10 simultaneous review workstation connections.
Minimum System Requirements
The system running Cirrus Review Software must meet the following minimum requirements:
* Operating systems: Windows XP Service Packs 2 and 3, Windows Vista Ultimate, Business and Enterprise supported. 64-bit operating systems are not supported.
* Processor: Intel Pentium IV, at least 1.5 GHz,or AMD Athlon, at least 1.8 GHz. Intel processors are recommended.
* Memory: 1 GB RAM; when running additional applications concurrently, more memory may be required.
* At least 20 GB available hard disk space.
* CD-ROM drive (for installation)
* 1024 x 768 pixel screen resolution; 32 bit color.
* Network interface card 100 Mbps
Note: Not all resolutions will work properly on wide-screen monitors.Cirrus analysis involves computational processing of large data sets,and therefore the review software performs best on a powerfulcomputing platform.
Recommended Graphics Cards
For desktop systems:
* ATI X1600 or above
* NVIDIA 8000 or above
For notebook systems:
* ATI Mobility Radeon X1600 or above
* NVIDIA Quadro FX360M or above
* NVIDIA 8000M series or above
* Mobile Intel Chipset 910 GML or above
This is where the ergonomic design meets the needs of modern visual field evaluation. Performing everything from a fast screening evaluation to manually controlled kinetic perimetry is easier than previously. OPTOPOL PTS 2000 Automated Perimeter brings to one of the world’s biggest field testing ranges and options, together with all Goldman stimulation sizes and stimulation colors used in perimetry. Together with the modern and intuitive software, all that is available at your fingertips.
The PTS automatic perimeter series are modern diagnostic tools for exact and fast testing of visual fields. Beside standard perimetry testing techniques, they employ all the latest visual field testing approaches saving time and provide cutting-edge precision and dependability.
UNIQUE FEATURES:
- Windows 10 Operating System for ease-of-use and support
- DICOM and EMR and wireless printing capability – standard
- All PTS perimeters have the peripheral testing capability
- Blue LED band around the unit to provide ambient light to the operator and patient
- Optional data transfer for your existing HFA perimeter
- Comprehensive 2 – year warranty on all units sold for a limited time
- Full Featured Projection Perimeter
- Kinetic Testing
- Blue/Yellow and Color Testing
- Fast Threshold Testing
- Statistical Analysis Package
- DICOM and EMR Compatible
- Wireless Network Printing
- Windows 10 Operating System
- Gaze Tracking
- Blink Monitoring
- Electronic Chin Rest
- Binocular Esterman Testing
- Peripheral Testing out to 180 Degrees
- LED Projection Source vs. Halogen
- The PTS automated perimeters are state-of-the-art
- diagnostic instruments for precise and fast testing of visual
- fields. They go beyond standard perimetry testing
- techniques to implement all of the latest visual field testings
- approaches, saving time and delivering cutting edge
- precision and reliability. Intuitive Windows-based software
- with powerful networking and EMR integration, combined
- with maintenance free and reliable hardware, creates the
- best tools available for visual field testing.
ALL THAT YOU NEED
- Complete set of standard perimetry tests.
- Variety of threshold algorithms and screening techniques.
- Binocular Driver’s Test, Flicker perimetry and Blue on Yellow.
- The complete palette of analysis tools for quick and thorough assessment of visual fields.
- Comparison and progression module available in standard package.
- Kinetic testing for quick evaluation of peripheral field loss.
- Standard test reports and global indices.
- Automatic and manual kinetic perimetry.
- 180° horizontal and 130° vertical testing range for peripheral screening.
- Aspherical bowl for compact dimensions.
- All Goldmann stimuli sizes and colors used in perimetry.
- 30-2, 24-2, and 10-2 testing fields.
THRESHOLD IN 3 MINUTES*
- Advanced Threshold strategy – quicker examination without loss in result resolution.
- 24-2/24A field tested in less than 3 minutes (30-2/30A in less than 4 minutes)*.
- Provides more detailed information than screening strategies in comparable duration.
SUPREME RELIABILITY
- High-resolution camera for precise monitoring of patients’ compliance.
- Blink control – no stimuli are omitted due to normal blinking, the test is put on hold until the eye is opened again.
- Eye tracking – analyses pupil movement and assures supreme reliability of test results.
- Voice messages assist operator and patient during the examination.
FLEXIBILITY FOR TIME
- Rich library of predefined test fields and programs.
- Custom test settings can be stored and accessed with a single touch.
- Follow-up tests can be performed by simple selection of base examination.
- Partial test results of not completed test can be continued at a later date.
- Built-in networking features – data can be accessed from anywhere within your network.
- Out of the box DICOM support.
- Storing visual field reports on the DICOM image server.
- DICOM Modality Worklist support.
- GDT interface and custom EMR’s based on text file interface.
* depends on the patient condition
NEW Optopol PTS 2000 PERIMETER – Upgrade your HFA with a new, full-featured projection perimeter running Windows 10 PRO with full networking, DICOM, etc. and a two-year warranty for over $10,000.00 less than comparable units! Third generation perimeter manufactured in Europe with exclusive sales. Full HFA data transfer and HFA trade-in program available!
Digital NM/M/FAG Retinal Camera Kowa VX-10α, NEW!
Two-In-One Mydriatic and Non-Mydriatic Fundus Camera
High functionality, high-quality images and easy to use, VX-10α is the ideal tool for eye-care photography.
VX-10α becomes the perfected fundus camera performing all non-mydriatic color, mydriatic-color and FA.
Please find all technical detail at the PDF belonging to this offer.
Scheimpflug Topographer Tomey TMS-5, NEW!
* High resolution
* Anterior + posterior map
* Pachymetry map
* Anterior chamber depth
* High speed measurement: 0.3 sec.
* Operates in all light conditions
bon "SIRIUS" - High Resolution 3D Rotating Scheimpflug Camera and topography system,
including software, electric table, computer and TFT display
The excellent combination between a rotating Scheimpflug camera and a Placido disk technique provides the best performances for measuring:
# Anterior and posterior corneal topography
(sagittal and tangential, curvature and elevation maps)
# Corneal Pachymetry (12 mm diameter)
# Anterior chamber analysis
# OPD analysis and visus simulation
# Keratoconus screening
Device features
# Refractive and cataract surgery planning tools
# Glaucoma screening
# Keratoconus screening
# IOP correction formulas
# Optical cornea analysis
# Cataract summary
# Glaucoma Summary
# Keratoconus Summary
Computerized Electrophysiology Device Tomey EP-1000 Pro, NEW!
The EP-1000 Pro is the essence of 10 years experience of developing electrophysiology instruments. It is an ISCEV conform electrophysiology diagnostic device in a compact shape. Standard examinations are: ERG, VEP, EOG, PERG and SWEEP VEP.
The examination procedure is automated and the easy-to-use program steps will guide you through the complete examination. That makes it possible to delegate this kind of examination to assistants. The EP-1000 Pro workstation provides full com-
puterized control of electrophysiology testing and data management.
Switching to a flash stimulated examination will automatically occlude the integrated monitor of the Ganzfeld dome. Selecting of pattern stimulation automatically opens the occlusion. These filters are automatically inserted upon respective program selection. Thus it represents the second level of EP-1000 Pro evolution.
Digital Hybrid Digital Fundus Camera Canon CX-1
Complete workstation incl. Digital Hybrid Digital Fundus Camera Canon CX-1 incl. Canon EOS-60D MarkII MED, Power-PC, HD-screen, electr. ophthalmic table, NEW!
The CX-1 is a MYD and Non-MYD hybrid digital retinal camera. It is extremely versatile with its 5 photography modes; colour. FAG, red free, cobalt and FAF (Fundus Auto Fluorescence). Making it ideal for screening and the diagnosis of the main eyes diseases.
Features
* Digital Retinal Camera,
* Hybrid camera MYD / Non MYD
* FAF (Fundus Auto Fluorescence), also in Non Myd
mode
* Use of EOS technology
* Advanced Stereo photography system
* Bundled Retinal Imaging Control Software
* Open connectivity and DICOM compliant
Canons CX-1 is a compact and portable hybrid retinal camera that combines both Mydriatic and Non-Mydriatic Modes, and switches between the two with a simple touch of a button.
Hybrid camera
Canons CX-1 is a compact and portable hybrid retinal camera that combines both Mydriatic and Non-Mydriatic Modes, As well as saving on equipment investment, this function also means that the examiners using the equipment can screen for more than one disease, e.g. AMD (Age-related Macular Degeneration), Glaucoma and diabetic retinopathy, with the same unit. This saves time and removes the need for repeat appointments.
5 Photography Modes
With the CX-1 following photography modes are available; Color, Red-free, Cobalt, Fluorescein Angiography and Fundus Autofluorescence (FAF) Alignment and observation with the CX-1 can be done through the viewfinder or by the large EOS LCD screen
FAF (Fundus Auto Fluorescence)
Detecting Auto fluorescence of the retina is an important indication of the retinas health. With the CX-1 it is possible to take FAF (Fundus Auto fluorescence) images, even in Non-Mydriatic mode.
Use of EOS Technology
Canons own EOS camera technology, with its renowned image processing capabilities, is adapted exclusively for medical use in the CX-1 to provide optimal retinal imaging in a compact and convenient system. The single onboard 15.1 MegaPixel digital camera handles five different photography modes with ease, including non-mydriatic FAF photography, allowing EOS imaging technology to benefit all retinal images from the CX-1.
Enhanced stereo photography function
Easy capture for stereo view, by using the stereo guide marks on EOS LCD in the non-mydriatic mode, or stereo unit (option) a stereo pair can be created and managed very simply
Bundled Retinal Imaging Control Software
Bundled Retinal Imaging Control Software (RICS) for full camera control and image optimalization. The software has extensive diagnostic tools for optimized workflow and patient management; e.g. Cup/Disc ratio calculation, compare studies, RGB channel display, stereo viewing
Open connectivity and DICOM compliant
The CX-1 with RICS has open connectivity with existing networks and is fully DICOM compliant.
Digital NM/M/FAG/ICG Retinal Camera Kowa VX-10i, NEW!
Two-In-One Non-Mydriatic and Mydriatic Fundus Camera.
Highly effective and ergonomically designed, the ideal tool for eye-care photography.
VX-10i, camera of extend possibilities with the ICG filter, VX-10i become the perfected fundus camera performing all non-mydriatic color, mydriatic color, FA and ICG.